Overview
Alerts 0
Sign in

Sites — multi-vendor estate

Active Faults — by severity

Energy Share — by vendor (30d)

Comfort — by site (24h)

Equipment — select to view live points

Points

PointValueVendor nameControlAlert
Select equipment from the tree.

Active Alerts

View all →
Select equipment to see its active alerts.

Alarms — FDD across all vendors

SevFindingSiteVendor

FDD Summary

Open Work Orders

PriTaskSite

Custom Alarm Rules — thresholds

RuleConditionSev

Anomaly Detection — statistical, 6h baseline

PointEquipment / SiteValuez

ESG Summary — 30 days

SiteEnergy (kWh)CostCarbon (kgCO₂e)Peak (kW)EUI (kWh/m²)

Benchmarking & Savings (M&V) — weather-normalized vs baseline

SiteEUIWeather-normTargetBaselineSavingsHDD/CDD

Demand & Peak — peak kW, load factor, 24h load profile

SitePeak kWAvg kWLoad factorLimit

Daily Carbon — kgCO₂e by site

Normalization Explorer — how each vendor's raw points map to the unified model

VendorRaw vendor nameRaw refCanonical nameUnitTags
Building:
Legend — equipment abbreviations
AHU · RLT — Air Handling Unit
CH · KAE · Chiller — Chiller (cooling plant)
BLR · KES · Boiler — Boiler (heating plant)
VAV — Variable Air Volume terminal
FCU — Fan Coil Unit
Zone · Raum — Zone / Room
OT — Operating Theatre · ICU — Intensive Care Unit
MSB · Zähler · Main Incomer — Electrical Meter / Switchboard
FACP · BMZ · Fire Panel — Fire Alarm Control Panel (incl. electric / diesel / jockey pumps)
DW · TWW · Domestic Water — Fresh / Domestic Water (tank, booster, metering)
ACS · ZUT · Access Control — Door Controllers / Card Readers
CCTV · VID — Video Surveillance (cameras, NVR)
ELV · AUF · Elevator — Lift / Vertical Transport
CRAC — Computer-Room A/C (precision cooling) · UPS · USV — Uninterruptible Power Supply
PDU — Power Distribution Unit · GEN · NOT — Standby Generator · ENV — Aisle Environment / Leak
Status
Normal / online
2Active alarms on the item
Vendor naming differs — SAUTER uses German codes (RLT, KAE, BMZ…), Honeywell uses Niagara codes (AHU, CH, FACP…), Schneider uses full English. Rosetta normalizes them all to one model.

Comfort by Site — 24h compliance

SiteComfortZones

Overall Comfort Index

Zones — temperature band & CO₂ compliance (last 24h)

ZoneSiteTemp %CO₂ %Overall

Asset Register — health, runtime, next service

EquipmentSiteHealthRuntime 7dFrequencyNext service

Detail

Select an asset to view its maintenance timeline.

Work Orders — any device

PriTaskStatus

Work order detail

Select a work order to manage replacement parts and complete it.

Parts Inventory — stock & reorder

Part #DescriptionForCostStock

PM Schedule & Timeline — how often each machine is serviced + what's next

EquipmentSiteFrequencyLast serviceNext dueStatusAction

Maintenance History — recent work across the estate

DateEquipmentTypeSummaryParts replacedCostTech

Data Quality — normalized coverage

Define New Element — custom equipment or virtual points

Delete equipment:

Sites & Settings — add a building, edit tariff / EUI / carbon (admin)

SiteTariffTarget EUICarbon %

Connectors & Integration — define the BMS API per building: vendor, protocol, driver, transport & endpoint (admin)

VendorBuildingProtocolDriverEndpointTransportStatusPointsFresh

Users & Roles — admin

NameEmailRole

Occupancy Schedules — per-site occupied hours & setpoints

SiteDaysOccupied hoursOccupied °CSetback °C

Audit Log — control actions

TimeActorActionTarget

Settings — configure Rosetta

Jump to any configuration area, set org-wide defaults, or personalize your own experience.

Global Defaults — org-wide (admin)

My Preferences — personal, saved on this device

Automation Rules — IF inputs THEN outputs, across any vendor

Building Scorecards — ranked composite performance

#SiteScoreGradeEnergyComfortReliabilityFaults

Portfolio Map

Prioritized Opportunities — ranked by avoidable cost

PriIssueSite / EquipmentCategoryAvoidable/yr

Savings by Category

Select an opportunity to see the recommendation.